Com fer un reset als comptadors de un Oki C5400

Visitas: 670
Posted: 14. June 2007
by:
Updated: 14. June 2007
by:

C5300n.

 1) Power on printer while holding both the + & - buttons simultaneously; release when “OKIUSER” is displayed.
2) Press either the + or – button until “ENGINE DIAG MODE” is displayed; press the Enter button and “DIAGNOSTIC MODE xx.xx.xx” will be displayed.
3) Press and hold both the - & On-line buttons simultaneously until “ENG DIAG LEVEL2” is displayed.
4) Press either the + or – button until “CONSUMABLE COUNTER SET” is displayed, press the Enter button; you are now in the menu to set various consumables.
5) Press either the + or – buttons to scroll through the various consumables, at the desired consumable (ie. “K-ID UNIT …” for the Black Image Drum Unit) press the Enter button and the last digit of the count will start flashing.
6) Press the Cancel button to decrease the digit amount or press the On-line button to increase the digit amount; press the + or – buttons to move along individual digits in the count.
7) Once the count is at the level you desire (I reset mine to 50), press and hold the On-line, Cancel, & Back buttons (yes, it’s 3 of them this time) simultaneously until the “*” reappears next to the count; you have reset that consumable’s count to the number you specified.
8) Press the + or – buttons to move to the next consumable and repeat at step 5.
9) Once all consumable counts have been set to desired amounts that are below their end-of-life thresholds, you can use the Back, +, & - buttons to exit through the menus (reverse of steps 2 through 4) until “INITIALIZING” is displayed.
10) You're finished! Now log in to the web interface with your browser and check to see the remaining life of your consumables.

 
  c9300n...

1 - Power ON printer while holding both the + & - buttons until “OKIUSER” message apear in LCD.
2) Press + or – button until “ENGINE DIAG MODE” is displayed;
3) Press "ENTER", will be displayed "DIAGNOSTIC MODE XX.XX.XX S-MODE"
4) Press + or – button until “NV-RAM INITIAL” is displayed
5) Press "ENTER" again;
6) Will appear "TABLE 1" message;
7) Press "ENTER" until "EXECUTING RESET" message appear. the "NV-RAM INITIAL" message will BLINK...
This procedure reset TONER, DRUM, FUSER and BELT...
8) power OFF printer, wait 10 sec, and power ON again... =)

To access Service Mode in C9300 power ON printer with 0, 1, 6, 7 at same time...

 
Oki c7200n drum reset?? by Anonymous (3/1/06 1:33 PM) reply + / -

1 - Power ON printer while holding both the + & - buttons until “OKIUSER” message apear in LCD.
2) Press + or – button until “ENGINE DIAG MODE” is displayed;
3) Press "ENTER", will be displayed "DIAGNOSTIC MODE XX.XX.XX S-MODE"
4) Press + or – button until “NV-RAM INITIAL” is displayed
5) Press "ENTER" again;
6) Will appear "TABLE 1" message;
7) Hold "ENTER" until "EXECUTING RESET" message appear. the "NV-RAM INITIAL" message will BLINK...
This procedure reset TONER, DRUM, FUSER and BELT...
8) power OFF printer, wait 10 sec, and power ON again... =)

 
c5300n drum reset?? by bLiTzJoN (6/17/06 7:56 AM) reply + / -

Found this on CNET/NY Times. I'm assuming it's a factory reset for everything.

Full user opinion
This printer tries to force you to buy expensive replacement toner cartridges and image drums well before their useful life is over (automatically shuts down after preset number of pages). To work around these limitations, you can do the following:

1. Turn machine on while pushing and holding the TWO up/down menu buttons at same time.
2. Menu window will show "OKI USER"
3. Scroll to " Engine Dialog Mode" is indicated. Push Enter button.
4. "Diagnostic Mode xx.xx.xx S-Mode is indicated.
5. Scroll to "NV-Ram initial" is indicated. Push ENTER.
6. Window shows "NV-Ram- Initial Table 1".
7. Push ONLINE and ENTER Buttons simultaneously and HOLD for 10 seconds after you see "Executing Reset" appear in menu window.
8. Restart printer.

All toner, drum, fuser and transfer figures return to 100%. Of course, if you are out of toner, you do need to refill the cartridges, but you can find refill toner and instructions on ebay (a bit messy, but cheaper than new cartridges). The drums, etc. won't work forever, but they will work longer than the artificial limits imposed by Okidata.

Here's the source http://tinyurl.com/lh36z

  
Oki C5200n
1. Turn machine on while pushing and holding the TWO up/down menu buttons at same time.
2. Menu window will show "OKI USER"
3. Scroll to " Engine Dialog Mode" is indicated. Push Enter button.
4. "Diagnostic Mode xx.xx.xx S-Mode is indicated.
5. Scroll to "NV-Ram initial" is indicated. Push ENTER.
6. Window shows "NV-Ram- Initial Table 1".
7. Push ONLINE and ENTER Buttons simultaneously and HOLD for 10 seconds after you see "Executing Reset" appear in menu window.
8. Restart printer.

All toner, drum, fuser and transfer figures return to 100%. Of course, if you are out of toner, you do need to refill the cartridges, but you can find refill toner and instructions on ebay (a bit messy, but cheaper than new cartridges). The drums, etc. won't work forever, but they will work longer than the artificial limits imposed by Okid